Otsing
Otsingukriteeriumid
Otsi:
Otsingukriteeriumile vastavad tooted
-
II 3G 2D Ex nR IIC T6 GcII 3G 2D Ex tb IIIC T 70 °C Db IP66IP66Thermosetting (GRP)
-
INOX Steel SensorEthylene Oxide (ETO) gas sensor0-20 ppmATEX 94/9/EC¾” NPT cable glandFast response
-
INOX Steel SensorCombustibles gases sensor0-100% vol.VQ-06¾” NPT cable glandATEX 94/9/ECFast response
-
4 gasesGas: HC or CH4 / O2 / CO / H2S0-100%LEL (HC/CH4)0-40vol% (O2)0-2000ppm (CO)0-200ppm (H2S)Lithium ionII 1G Ex ia IIC T4 Ga
-
5 gasesGas: HC or CH4 / O2 / CO / H2S / CO2 or SO20-100%LEL (HC/CH4)0-40vol% (O2)0-2000ppm (CO)0-200ppm (H2S)0-10vol%/0-10000ppm (CO2)0-100ppm (SO2)AA or Lithium ionII 1G Ex ia IIC T4 Ga
-
INOX Steel SensorNitrogen (NH3) gas sensor0-100 ppmATEX 94/9/EC¾” NPT cable glandFast response
-
INOX Steel SensorCarbon Monoxide (CO) gas sensor0-200 ppmATEX 94/9/EC¾” NPT cable glandFast response
-
InfraredHydrocarbons (HC) gas sensor0-5% vol.0-100% vol.0-100% LEL4-20mA9-24 VDC
-
220 x 120 mm8 x M16 cable gland4 x M20 cable gland1 x M25 plug4 x M20 plug25x WDU4 + 6x PE
-
Ex-tech Signalling Plahvatuskindel (ATEX / IECEx) Heli- ja Tulesignaali Kombinatsioon (316L) – SB125ATEX, IECExZone 1 & Zone 2 (Gas/Vapour) and Zone 21 & Zone 22 (Dust/Powder)Housing – 316L stainless steel; Lens – Borosilicate glass 3.3316L stainless steel backplateLED, XENONIP66/IP67Can be triggered together or independently
-
ATEX, IECExZone 1 & Zone 2 (Gas/Vapour) and Zone 21 & Zone 22 (Dust/Powder)Housing – Glass-Reinforced Polyester (GRP) with UV-resistant paintIP66/IP67Compatible with PLC, ESD, and DCS systems
-
ATEX, IECEx, optional SIL2 IEC61508Zone 1 & Zone 2 (Gas/Vapour) and Zone 21 & Zone 22 (Dust/Powder)Housing – 316L Stainless Steel for durability in harsh environmentsIP66/IP67Compatible with PLC, ESD, and DCS systemsAvailable in two versions – standard push button and push button with key reset
-
ATEX, IECEx, optional SIL2 IEC61508Zone 1 & Zone 2 (Gas/Vapour) and Zone 21 & Zone 22 (Dust/Powder)Housing – Glass-Reinforced Polyester (GRP) with UV-resistant paintIP66/IP67Compatible with PLC, ESD, and DCS systemsAvailable in two versions – standard push button and push button with key reset
-
ATEX, IECExZone 1 & Zone 2 (Gas/Vapour) and Zone 21 & Zone 22 (Dust/Powder)Housing – 316L stainless steel; Lens – Borosilicate glass 3.3316L stainless steel backplateLED, XENONIP66/IP67Can be triggered together or independently
-
Zones 1, 2, 21, and 22IP66EN 44300 aluminum alloyLumen outputs from 17350lm up to 33100lm
-
IP66 ProtectionSuitable for Zones 1, 2, 21, 22Durable Aluminum HousingAvailable in both symmetrical 81° and asymmetrical 50° beam anglesLumen outputs from 17,365lm to 33,120lm
-
Ex II 2 GD Ex e mb q IIC T4 Tamb 55°C-40°C ... +55°C30W LEDEmergency available
-
II 2 G Ex d / Exe / Exia IIC GbII 2 D Ex tb IIIC Db1" NPTNickel plated brassFor armoured cable-60°C ÷ +180°C
-
II 2 G Ex d / Exe / Exia IIC GbII 2 D Ex tb IIIC Db3" NPTNickel plated brassFor armoured cable-60°C ÷ +180°C
-
II 2 G Ex d / Exe / Exia IIC GbII 2 D Ex tb IIIC Db3/4" NPTNickel plated brassFor armoured cable-60°C ÷ +180°C