Поиск
Критерии поиска
Поиск:
Товары, соответствующие критериям поиска
-
II 2D Ex tb IIIC T85°C DbZone 21 and Zone 22Temp = -20°C ...+55°CATEX, EN, IECExIP65, IEC/EN 605296 Poles (3 wafers)
-
II 2D Ex tb IIIC T85°C DbZone 21 and Zone 22Temp = -20°C ...+55°CATEX, EN, IECExIP65, IEC/EN 605294 Poles (2 wafers)
-
II 2D Ex tb IIIC T85°C DbZone 21 and Zone 22Temp = -20°C ...+55°CATEX, EN, IECExIP65, IEC/EN 605293 Poles
-
II 2D Ex tb IIIC T85°C DbZone 21 and Zone 22Temp = -20°C ...+55°CATEX, EN, IECExIP65, IEC/EN 605293/4 Poles
-
II 3G 2D Ex nR IIC T6 GcII 3G 2D Ex tb IIIC T 70 °C Db IP66IP66Thermosetting (GRP)
-
II 3G 2D Ex nR IIC T6 GcII 3G 2D Ex tb IIIC T 70 °C Db IP6XIP66Aluminium alloy
-
II 3G 2D Ex nR IIC T6 GcII 3G 2D Ex tb IIIC T 70 °C Db IP66IP66Thermosetting (GRP)
-
II 3G 2D Ex nR IIC T6 GcII 3G 2D Ex tb IIIC T 60/70 °C Db IP66IP66Thermosetting (GRP)
-
II 3G 2D Ex nR IIC T6 GcII 3G 2D Ex tb IIIC T 60/70 °C Db IP66IP66Aluminium alloy
-
II 3G 2D Ex nR IIC T6 GcII 3G 2D Ex tb IIIC T 60/70 °C Db IP66IP66Aluminium alloy
-
II 3G 2D Ex nR IIC T6 GcII 3G 2D Ex tb IIIC T 70 °C Db IP66IP66Thermosetting (GRP)
-
II 3G 2D Ex nR IIC T6 GcII 3G 2D Ex tb IIIC T 70 °C Db IP6XIP66Aluminium alloy
-
II 3G 2D Ex nR IIC T6 GcII 3G 2D Ex tb IIIC T 70 °C Db IP66IP66Thermosetting (GRP)
-
ATEX, IECExZone 1 & Zone 2 (Gas/Vapour) and Zone 21 & Zone 22 (Dust/Powder)Housing – Glass-Reinforced Polyester (GRP) with UV-resistant paintIP66/IP67Compatible with PLC, ESD, and DCS systems
-
ATEX, IECEx, optional SIL2 IEC61508Zone 1 & Zone 2 (Gas/Vapour) and Zone 21 & Zone 22 (Dust/Powder)Housing – Glass-Reinforced Polyester (GRP) with UV-resistant paintIP66/IP67Compatible with PLC, ESD, and DCS systems
-
ATEX, IECEx, optional SIL2 IEC61508Zone 1 & Zone 2 (Gas/Vapour) and Zone 21 & Zone 22 (Dust/Powder)IP66/IP67Compatible with PLC, ESD, and DCS systemsHousing – 316L Stainless Steel with UV-resistant paint
-
ATEX, IECEx, optional SIL2 IEC61508Zone 1 & Zone 2 (Gas/Vapour) and Zone 21 & Zone 22 (Dust/Powder)Housing – 316L Stainless Steel for durability in harsh environmentsIP66/IP67Compatible with PLC, ESD, and DCS systemsAvailable in two versions – standard push button and push button with key reset
-
ATEX, IECEx, optional SIL2 IEC61508Zone 1 & Zone 2 (Gas/Vapour) and Zone 21 & Zone 22 (Dust/Powder)Housing – Glass-Reinforced Polyester (GRP) with UV-resistant paintIP66/IP67Compatible with PLC, ESD, and DCS systemsAvailable in two versions – standard push button and push button with key reset
-
ATEX, IECEx, optional SIL2 IEC61508Zone 1 & Zone 2 (Gas/Vapour) and Zone 21 & Zone 22 (Dust/Powder)Housing – Glass-Reinforced Polyester (GRP) with UV-resistant paintIP66/IP67Compatible with PLC, ESD, and DCS systemsAvailable in two versions – standard push button and push button with key reset
-
Designed to be welded to a bulkhead or deck.Material: Mild Steel, Stainless Steel, Aluminium and other materials under request.To be sealed with standard or EMC HF blocks, compression systems and accessories.
-
Designed to be welded to a bulkhead or deck.Materials: Mild Steel, Stainless Steel.To be sealed with standard or EMC HF blocks, compression systems and accessories
-
Available to seal services from 4mm up to 170mm of external diameterTolerant up to 7 mm.Designed to be installed using Hawke Sleeves (welded, bolted or casted).No extra tools are required for its installation.
-
Designed to be installed using Hawke Sleeves (welded, bolted or casted) and standard HF blocksManufactured in intumescent elastomer polymer with stainless steel front and back plates. Plates also available in mild steel.No extra tools are required for its installation.
-
Made of zero halogen, intumescent elastomeric polymer.No modification of the block needed during installation. Zero waste material.Four sealing grooves within the internal faces ensure correct contact all along the cable/pipe.Minimum and maximum sealing range is marked on the blocks.
-
ATEX, IECExCertified for Zone 1 & Zone 2 (Gas/Vapour) and Zone 21 & Zone 22 (Dust/Powder)Enclosure – Glass-Reinforced Polyester (GRP)IP66/IP67Up to three tones selectable from 59 pre-recorded tones
-
ATEX, IECExEnclosure – Glass-Reinforced Polyester (GRP)IP66/IP67Up to three tones selectable from 59 pre-recorded tonesCertified for Zone 1 & Zone 2 (Gas/Vapour) and Zone 21 & Zone 22 (Dust/Powder)
-
ATEX, IECExZone 1 and Zone 2 Zone 21 and Zone 22Red, Amber, Blue, Green, Yellow, ClearResistant to corrosion, UV rays, high and low temperaturesIP66/IP67Enclosure – Stainless steel 316L, Lens – Tempered borosilicate glassLED (steady, rotary, or flashing), XENON (various intensities)
-
ATEX, IECExZone 1 and Zone 2 Zone 21 and Zone 22Red, Amber, Blue, Green, Yellow, ClearResistant to corrosion, UV rays, high and low temperaturesIP66/IP67Materials: Enclosure – Stainless steel 316L, Lens – Tempered borosilicate glassLED (steady, rotary, or flashing), XENON (various intensities)
-
Zones 1, 2, 21, and 22IP66288x583x65 mmEN 44300 aluminum alloy




























