Designed to be welded to a bulkhead or deck.Material: Mild Steel, Stainless Steel, Aluminium and other materials under request.To be sealed with standard or EMC HF blocks, compression systems and accessories.
-
Designed to be welded to a bulkhead or deck.Materials: Mild Steel, Stainless Steel.To be sealed with standard or EMC HF blocks, compression systems and accessories
-
Designed to fill spaces within the frameMade from high-quality, durable materials for long-lasting performance.No special tools are required for installation.Certified for use in EX zones and hazardous environments.
-
Available to seal services from 4mm up to 170mm of external diameterTolerant up to 7 mm.Designed to be installed using Hawke Sleeves (welded, bolted or casted).No extra tools are required for its installation.
-
Designed to be installed using Hawke Sleeves (welded, bolted or casted) and standard HF blocksManufactured in intumescent elastomer polymer with stainless steel front and back plates. Plates also available in mild steel.No extra tools are required for its installation.
-
II 2 G Ex d / Exe / Exia IIC GbII 2 D Ex tb IIIC Db1 1/2" NPTNickel plated brassFor armoured cable-60°C ÷ +180°C
-
II 2 G Ex d / Exe / Exia IIC GbII 2 D Ex tb IIIC Db1 1/4" NPTNickel plated brassFor armoured cable-60°C ÷ +180°C
-
II 2 G Ex d / Exe / Exia IIC GbII 2 D Ex tb IIIC Db1" NPTNickel plated brassFor armoured cable-60°C ÷ +180°C
-
II 2 G Ex d / Exe / Exia IIC GbII 2 D Ex tb IIIC Db1/2" NPTNickel plated brassFor armoured cable-60°C ÷ +180°C
-
II 2 G Ex d / Exe / Exia IIC GbII 2 D Ex tb IIIC Db2 1/2" NPTNickel plated brassFor armoured cable-60°C ÷ +180°C
-
II 2 G Ex d / Exe / Exia IIC GbII 2 D Ex tb IIIC Db2" NPTNickel plated brassFor armoured cable-60°C ÷ +180°C
-
II 2 G Ex d / Exe / Exia IIC GbII 2 D Ex tb IIIC Db3" NPTNickel plated brassFor armoured cable-60°C ÷ +180°C
-
II 2 G Ex d / Exe / Exia IIC GbII 2 D Ex tb IIIC Db3/4" NPTNickel plated brassFor armoured cable-60°C ÷ +180°C
-
Exd IIC Gb, Exe IIC Gb, Extb IIIC Dbfor non-armouredfor plastic insulated cables
-
Exd IIC Gb, Exe IIC Gb, Extb IIIC Dbfor non-armouredfor plastic insulated cables
-
Exd IIC Gb, Exe IIC Gb, Extb IIIC Dbfor single wire armourfor wire braidfor steel tape armourfor plastic insulated
-
Exd IIC Gb, Exe IIC Gb, Extb IIIC Dbfor single wire armourfor wire braidfor steel tape armourfor plastic insulated
-
Exd IIC Gb, Exe IIC Gb, Extb IIIC Dbfor single wire armourfor wire braidfor steel tape armourfor plastic insulated