Search

Search Criteria

Search:

Products meeting the search criteria

Sort By:
Show:
  • Ex pressure relay
    relative pressure
    from -1 to 400 bar
    1 or 2 change over (SPDT)
  • Ex pressure relay
    -1 to 1000 bar (relative pressure)
    0 to 90 bar (differential pressure)
    1 or 2 change over (SPDT)
  • Ex pressure relay
    -1 to 1000 bar (relative pressure)
    0 to 100 bar (differential pressure)
    1 or 2 change over (SPDT)
    SIL
  • Ex pressure relay
    relative pressure
    0.5 to 40 bar
    NBR or FKM diaphragm
    SIL
  • Ex pressure relay
    -500 to 1100 mbar (relative pressure)
    0 to 1100 mbar (differential pressure)
    1 or 2 change over (SPDT)
    SIL
  • Ex pressure relay
    -1.5 to 1 mbar (relative pressure)
    0 to 2.5 mbar (differential pressure)
    1 change over (SPDT)
  • Ex pressure relay
    relative pressure
    from -1 to 20 bar
    1 pneumatic cell NO or NF
  • Ex temperature relay
    direct bulb or capillary
    -50..+600°C
    1 or 2 change over(SPDT)
  • Ex temperature relay
    direct bulb or capillary
    -90..+380°C
    1 or 2 change over(SPDT)
    SIL
  • Ex temperature relay
    with capillary
    -20..+210°C
    1 switch
    SIL
  • Ex temperature relay
    direct bulb or capillary
    -20..+250°C
    1 or 2 change over(SPDT)
  • Intrinsically safe relay
    II (1) GD [Ex ia] IIC or [Ex ia] IIB or [Ex iaD]
    Intrinsically safe relay
    Input: Switch or proximity sensor
    Output: Switch (5A – 250V) or transistor (5kHz)
    SIL 2 according to IEC 61508
    NAMUR
  • Motor protection relay 3P
    II 2 G Ex d IIB T6/T5 Gb
    II 2 D Ex tb IIIC T85 C/T100 C Db
    -60°C ... +60°C
    1,00-1,60A
    660 VAC
  • Motor protection relay 3P
    II 2 G Ex d IIB T6/T5 Gb
    II 2 D Ex tb IIIC T85 C/T100 C Db
    -60°C ... +60°C
    1,60-2,50A
    660 VAC
  • Motor protection relay 3P
    II 2 G Ex d IIB T6/T5 Gb
    II 2 D Ex tb IIIC T85 C/T100 C Db
    -60°C ... +60°C
    2,50-4,00A
    660 VAC
  • Motor protection relay 3P
    II 2 G Ex d IIB T6/T5 Gb
    II 2 D Ex tb IIIC T85 C/T100 C Db
    -60°C ... +60°C
    4,00-6,60A
    660 VAC
  • Motor protection relay 3P
    II 2 G Ex d IIB T6/T5 Gb
    II 2 D Ex tb IIIC T85 C/T100 C Db
    -60°C ... +60°C
    6,60-10,00A
    660 VAC
  • Motor protection relay 3P
    II 2 G Ex d IIB T6/T5 Gb
    II 2 D Ex tb IIIC T85 C/T100 C Db
    -60°C ... +60°C
    0,20-0,35A
    660 VAC
  • Motor protection relay 3P
    II 2 G Ex d IIB T6/T5 Gb
    II 2 D Ex tb IIIC T85 C/T100 C Db
    -60°C ... +60°C
    10,00-16,00A
    660 VAC
  • Motor protection relay 3P
    II 2 G Ex d IIB T6/T5 Gb
    II 2 D Ex tb IIIC T85 C/T100 C Db
    -60°C ... +60°C
    0,35-0,60A
    660 VAC
  • Motor protection relay 3P
    II 2 G Ex d IIB T6/T5 Gb
    II 2 D Ex tb IIIC T85 C/T100 C Db
    -60°C ... +60°C
    0,60-1,00A
    660 VAC