Search

Search Criteria

Search:

Products meeting the search criteria

Sort By:
Show:
  • Assembly set for heating tapes
    II 2G Ex e IIC T2, T3 Gb
    II 2D Ex tb IIIC T200 °C, T195 °C Db
    Heat shrink connection
    Silicone (cold connection)
    Max. operating temp: +200°C
  • Assembly set for heating tapes
    II 2G Ex e IIC T5 Gb
    II 2D Ex tb IIIC T95 °C Db
    HOT - HOT connection
    HOT - POWER CABLE connection
    -60 °C ... +200 °C
  • Assembly set for heating tapes
    II 2G Ex e IIC T5 Gb
    II 2D Ex tb IIIC T95 °C Db
    Silicone (cold connection)
    Max. operating temp: +85°C
  • Assembly set for heating tapes
    non Ex
    HOT - HOT connection
    HOT - POWER CABLE connection
    -20 °C ... +85 °C
  • Assembly set for heating tapes
    II 2G Ex e IIC T5 Gb
    II 2D Ex tb IIIC T95 °C Db
    Heat shrink connection
    Max. operating temp: +85°C
  • Assembly set for heating tapes
    II 2G Ex e IIC T5 Gb
    II 2D Ex tb IIIC T95 °C Db
    Silicone (cold connection)
    Max. operating temp: +85°C
  • Assembly set for heating tapes
    II 2G Ex e IIC T5 Gb
    II 2D Ex tb IIIC T95 °C Db
    Heat shrink connection
    Max. operating temp: +85°C
  • Assembly set for heating tapes
    II 2G Ex e IIC 200 °C (T2), T3, T4 Gb
    II 2D Ex tb IIIC
    Silicone (cold connection)
    Max. operating temp: +200°C
  • Assembly set for heating tapes
    II 2G Ex e IIC 200 °C (T2), T3, T4 Gb
    II 2D Ex tb IIIC T200 °C, T195 °C, T130 °C Db
    Heat shrink connection
    Max. operating temp: +200°C
  • Junction box for heating tapes
    II 2G Ex e IIC T6, T5 Gb
    II 2D Ex tb IIIC T80 °C, T95 °C Db
    CE
    -55°C ... +100°C
  • Junction box for heating tapes
    II 2G Ex e IIC T6, T5 Gb
    II 2D Ex tb IIIC T80 °C, T95 °C Db
    CE
    -55°C ... +100°C
  • Junction box for heating tapes
    II 2G Ex e IIC T5 Gb
    II 2D Ex tb IIIC T 95 °C Db
    Single / Double
    For heat shrink connection
    For cold (silicone) connection
    -55°C ... + 55°C
  • Junction box for heating tapes
    non Ex
    Single / Double
    For heat shrink connection
    For cold (silicone) connection
    -25°C ... +40°C
  • Junction box for heating tapes
    II 2G Ex e IIC T5, T6 Gb
    II 2D Ex tb IIIC T95 °C, T80 °C Db
    Single / Double
    For heat shrink connection
    For cold (silicone) connection
    -55°C ... + 55°C
  • Junction box for heating tapes
    non Ex
    Single / Double / Triple
    For heat shrink connection
    For cold (silicone) connection
  • Junction box for heating tapes
    II 2G Ex e II 200 °C (T2), T3, T4 Gb
    II 2D Ex tb II 2D Ex tb IIIC
    Single / Double / Triple
    For heat shrink connection
    For cold (silicone) connection
    -55°C ... + 55°C
  • Junction box for heating tapes
    II 2G Ex e IIC T6, T5 Gb
    II 2D Ex tb IIIC T80 °C, T95 °C Db
    Single / Double / Triple
    For heat shrink connection
    For cold (silicone) connection
    -55°C ... + 55°C
  • Heating cable EKL Light
    EN 62395-1
    ATEX certified
  • Heating cable EKL Medium
    II 2G Ex e II
    II 2D Ex tD A21
    CE
  • Heating cable EKL Premium
    II 2G Ex e II
    II 2D Ex tD A21
    CE
  • Heating cable FT
    For pipes and roofs
    Heating cable FT
    Šildymo kabelis FT
    Apsildes kabelis FT
    Греющий кабель FT
  • Heating cable HT
    Max. oper. temp: 250 C
    Heating cable HT
    Šildymo kabelis HT
    Apsildes kabelis HT
    Греющий кабель HT
  • Heating cable Mineral
    II 2G Ex e II T1 à T6 Gb
    ATEX certified
  • Heating cable MT
    For heavy applications
    Heating cable MT
    Šildymo kabelis MT
    Apsildes kabelis MT
    Греющий кабель MT
  • Heating cable PT
    High power cables
    Heating cable PT
    Šildymo kabelis PT
    Apsildes kabelis PT
    Греющий кабель PT
  • Heating cable PT2
    For snow and ice on ramps
    Heating cable PT2
    Šildymo kabelis PT2
    Apsildes kabelis PT2
    Греющий кабель PT2
  • Heating cable ST
    For pipes, roofs, gutters
    Heating cable ST
    Šildymo kabelis ST
    Apsildes kabelis ST
    Греющий кабель ST
  • Heating tape HSB
    Self-limiting
    II 2G Ex e IIC 200 °C (T2), T3, T4 Gb
    switched off: +200 °C
    15 W/m, 25 W/m, 30 W/m, 45 W/m, 60 W/m
    AC 208 V up to 254 V
  • Heating tape HSTB
    Self-limiting
    II 2G Ex e IIC T2, T3 Gb
    switched off: +250 °C
    30 W/m, 45 W/m, 60 W/m, 75 W/m, 90 W/m
    AC 208 V up to 254 V
  • Heating tape MSB
    Self-limiting
    II 2G Ex e IIC 200 °C (T2), T3, T4 Gb
    switched off :+130 °C
    10 W/m, 15 W/m, 25 W/m, 30 W/m, 40 W/m